Difference between revisions of "Main House Electricity System"
(Created page with "Deep cycle battery system in the main house The main house has a 24 Volt [V] battery system with a capacity of 420 Ampere-hours [Ah]. The battery system consists of four dee...") |
|||
Line 1: | Line 1: | ||
Deep cycle battery system in the main house | Deep cycle battery system in the main house | ||
+ | |||
+ | Back to [[Main Page]]. | ||
The main house has a 24 Volt [V] battery system with a capacity of 420 Ampere-hours [Ah]. | The main house has a 24 Volt [V] battery system with a capacity of 420 Ampere-hours [Ah]. |
Revision as of 13:36, 20 August 2020
Deep cycle battery system in the main house
Back to Main Page.
The main house has a 24 Volt [V] battery system with a capacity of 420 Ampere-hours [Ah]. The battery system consists of four deep cycle batteries of the type 12 FS 210 by Rolls Battery. Each individual battery has an output voltage of 12 V and a capacity of 210 Ah at a discharging rate of 20 hours (please check datasheets for lower discharging rates). The four batteries are parallel- and series-connected, which doubles the system’s voltage and capacity.
As with all deep cycle batteries, they shouldn’t be drained to less than 20% of their capacity, which results in a usable capacity of 336 Ah with 24 V (~8,000 Watt-hours [Wh]) after purchase. If the hour rate (time to discharge the battery) is closer to 10 hours, the usable capacity fluctuates around 296 Ah with 24 V (~7,100 Wh). Please note that these numbers will be lower after long-term usage.